Export · IEC / BS / EN / SANS · Est. 1972 · 54 Years

International Standards Export Cables

National Cables runs two BIS-certified manufacturing tracks: IS 694:2010 for PVC / FR / FR-LSH fixed and flexible wiring, and IS 17048:2018 for LSZH / HFFR thermoplastic LSH1 at 90 °C, mapped to H07Z-K. Conductors are 99.97% Electrolytic Grade Purity (Conductivity ≥ 101% IACS). Export builds are set to the quoted standard with required insulation wall and core identification across H07V-K, H05V-K, H07Z-K, H05VV-F / H07VV-F, NYY, NYM, SANS 1507, and BS 6004.

9+
International designations mapped
50+
Countries where these standards apply
694 + 17048
Dual BIS manufacturing tracks
54
Years · Est. 1972
PVC / FR Track
IS 694:2010 · 1100 V class
Fixed and flexible single-core, FR and FR-LSH (PVC), and PVC multicore power/control flex — all under the IS 694:2010 BIS scope with 650/1100 V rating where applicable.
LSZH / HFFR Track
IS 17048:2018 · 90 °C LSH1
Halogen-free flexible single-core follows IS 17048:2018 with thermoplastic HFFR (LSH1), 90 °C continuous service, and international mapping to H07Z-K.
Export Range

9 export specifications.

IEC 60227-3 · EN 50525-2-31
H07V-K / H07V-R / H07V-U
450/750V · Class 5 flex (K) · Class 2 strand (R) · Class 1 solid (U)
Single-core PVC installation wire for panel wiring, fixed installation, and flexible tails. IS 694:2010 certified at 650/1100V on the same TI1 PVC insulation.
Europe · Africa · Middle East
IEC 60227-3 · EN 50525-2-31
H05V-K / H05V-U
300/500V · Class 5 flex (K) · Class 1 solid (U)
Light-duty single-core PVC wire for appliance wiring, equipment internal wiring, and OEM flex tails. IS 694:2010 certified at 650/1100V on the same TI1 PVC insulation.
Europe · Middle East · Global OEM
EN 50525-3-41 · IS 17048:2018
H07Z-K
450/750V · Class 5 flex · LSZH/HFFR · 90°C continuous
Halogen-free, low-smoke flexible single-core wire for metro, rail, data centres, and public infrastructure. IS 17048:2018 certified. IEC 60754 and IEC 61034-2 compliant.
Europe · Metro & Rail · Infrastructure tenders
IEC 60227-5 · EN 50525-2-11
H05VV-F / H07VV-F
300/500V (H05) · 450/750V (H07) · Class 5 · 2–5 core
PVC insulated and sheathed flexible multicore cord for appliance connections, portable equipment, and industrial leads. Standard flexible cord designation globally.
Global — appliances & portable equipment
DIN VDE 0281-1
NYM-J / NYM-O
300/500V · Class 2 stranded · PVC/PVC · 2–5 core
Unscreened PVC multicore building cable for fixed indoor installation. The standard building wire for residential, commercial, and light industrial wiring across German-standard markets.
Germany · East Africa · Middle East
IEC 60502-1 · VDE 0276-603
NYY-J / NYY-O
0.6/1kV · Class 2 stranded · PVC/PVC · 1–5 core
Unarmoured PVC power cable for fixed indoor and outdoor installation, including direct burial in conduit. Standard power distribution cable for commercial and industrial projects.
Europe · GCC · North & East Africa
BS 6004:2012+A1:2020 · BS 6231
BS 6004 · BS 6231
450/750V (6491X) · 600/1000V (BS 6231) · Single core
British standard single-core PVC building wire (6491X) and panel wire (BS 6231). Direct IS 694:2010 lineage — same TI1 PVC insulation, IS 694:2010 certified at 650/1100V.
East Africa · Gulf States · UK specifications
SANS 1507 · Compulsory VC 8075
SANS 1507
300/500V (Part 2) · 0.6/1kV (Part 3) · PVC insulated
South Africa's compulsory cable standard for building wire and PVC power distribution. Conforming product available for SADC export markets. SABS mark testing available on request.
South Africa · Botswana · Namibia · Zimbabwe · SADC
VDE 0250 · IEC 60227-7
YY Control Cable
300/500V · Class 5 flex · PVC/PVC · 2–30 core
Unscreened multicore control cable for industrial automation, machine tooling, HVAC, and panel wiring. IS 694:2010 certified at 650/1100V on the same PVC construction.
Europe · GCC · Africa · Machine builders

Conformance: National Cables manufactures to IS 694:2010 (BIS Certified) and IS 17048:2018 (BIS Certified). Export configurations are documented by BIS track, insulation wall, and core identification. H07Z-K is supplied on the IS 17048:2018 line. Technical equivalence documentation and pre-dispatch test packs are available.
Standards Map

BIS Mapping

Class 5 focus: stock alignment is H07V-K and H05V-K. H07V-U and H07V-R are project-specific. NYY is unarmoured / unscreened power flex, and NYM is unscreened multicore. Both use IS 694:2010 Type D PVC baseline with 650/1100 V where applicable.

International Standard Designation Voltage BIS / product mapping Markets Page
IEC 60227-3H07V-K (Class 5 flexible) — primary / stock450/750VIS 694:2010 — single-core flexible / FR · 1100 V classEurope · Africa · Middle EastView →
IEC 60227-3H05V-K (Class 5 flexible) — primary / stock300/500VIS 694:2010 — FR single core (light) · 1100 V classEurope · Middle East · GlobalView →
IEC 60227-3H07V-U (solid) · H07V-R (stranded) — project-specific / on request450/750VIS 694:2010 — fixed installation · confirm lead timeEurope · Africa · Middle EastView →
DIN VDE 0281NYM-J · NYM-O — unscreened multicore300/500V (label)IS 694:2010 multicore — Type D PVC · 650/1100 V · no screen layerGermany · East Africa · Middle EastView →
IEC 60502-1 / VDE 0276NYY-J · NYY-O — unarmoured / unscreened power flex0.6/1kV (label)IS 694:2010 multicore — Type D PVC · 650/1100 V · no armoured / screened construction in this offerEurope · GCC · AfricaView →
SANS 1507Part 2 · Part 3300/500V · 0.6/1kVIS 694:2010 single + multicoreSouth Africa · SADCView →
BS 6004 / BS EN 505256491X · H07V-K flexible450/750VIS 694:2010 FR single coreEast Africa · Gulf · UKView →
BS 6231Tri-rated / 6231Y600/1000VIS 694:2010 single core flexibleEast Africa · Gulf · UKView →
VDE 0250 / IEC 60227-7YY — unscreened control cable (Class 5 flexible)300/500VIS 694:2010 multicore flexible control cableEurope · GCC · Africa · Machine buildingView →
IEC 60227-5H05VV-F · H07VV-F (Class 5 · -F)300/500V · 450/750VIS 694:2010 multicore flexibleGlobal — appliance and industrialProduct → · IEC →
EN 50525-3-41H07Z-K — LSZH flexible (LSH1)Per IS 17048:2018 / project datasheetIS 17048:2018 only — thermoplastic LSH1 · not IS 694:2010Europe · global tendersView →

IS 694:2010 Margins

Voltage Margins

For PVC lines mapped to IS 694:2010, U₀/U comparisons with harmonised labels are listed in the table below. H07Z-K / IS 17048:2018 uses a separate LSZH insulation system.

International StandardRated U₀/UIS 694:2010 (PVC) U₀/UIS 694:2010 vs international (U₀/U)
H07V (IEC 60227-3)450/750V650/1100V+44% p-e · +47% p-p
H05V (IEC 60227-3)300/500V650/1100V+117% p-e · +120% p-p
NYM (VDE 0281)300/500V650/1100V+117% p-e · +120% p-p
NYY (IEC 60502-1)600/1000V650/1100V+8% p-e · +10% p-p
BS 6004 6491X450/750V650/1100V+44% p-e · +47% p-p

Dossiers

Equivalence Dossiers

For projects where VDE, SABS, or BASEC marks are preferred, our engineering team provides a Technical Equivalence Dossier comparing IS-certified performance against the international reference for consultant review.

Request a Technical Equivalence Dossier →
Certification

Mark testing and documentation.

HAR (CENELEC), VDE, BASEC, and SABS mark testing is available on request for volume export orders through accredited IECEE CB bodies. H07RN-F (rubber/EPR) is outside the current range — no rubber extrusion line.

Every export shipment includes full IS 694:2010 or IS 17048:2018 BIS test documentation, routine test declarations, and RoHS/REACH material declarations.

Export Enquiries

Send your specification for capability confirmation, technical equivalence documentation, and quotation. 24-hour response.